CVE Feed

    Dashboard / CVE / CVE-2017-6015

    CVE-2017-6015

    Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.

    Published:May 11, 2018
    Last Modified:Nov 21, 2024
    EPS:May 11, 2018
    EPSS Score:0.00054
    CVSS Score:7.8

    Affected Products

    Vendor
    Rockwellautomation
    Product
    Factorytalk Activation

    Exploits

    No exploit reference

    Common Attack Pattern Enumeration and Classification (CAPEC)

    Common Vulnerability Scoring System

    Attack Vector
    Network
    Adjacent
    Local
    Physical
    Privileges Required
    None
    Low
    High
    User Interaction
    None
    Required
    Scope
    Unchanged
    Changed
    Confidentiality
    None
    Low
    High
    Integrity
    None
    Low
    High
    Availability
    None
    Low
    High