CVE Feed

    Dashboard / CVE / CVE-2018-10601

    CVE-2018-10601

    IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an "echo" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow.

    Published:Jun 5, 2018
    Last Modified:Nov 21, 2024
    EPS:Jun 5, 2018
    EPSS Score:0.00123
    CVSS Score:8.2

    Affected Products

    Vendor
    Philips
    Product
    Avalon Fetal\/maternal Monitors Fm20
    Vendor
    Philips
    Product
    Avalon Fetal\/maternal Monitors Fm20 Firmware
    Vendor
    Philips
    Product
    Avalon Fetal\/maternal Monitors Fm30
    Vendor
    Philips
    Product
    Avalon Fetal\/maternal Monitors Fm30 Firmware
    Vendor
    Philips
    Product
    Avalon Fetal\/maternal Monitors Fm40
    Vendor
    Philips
    Product
    Avalon Fetal\/maternal Monitors Fm40 Firmware
    Vendor
    Philips
    Product
    Avalon Fetal\/maternal Monitors Fm50
    Vendor
    Philips
    Product
    Avalon Fetal\/maternal Monitors Fm50 Firmware
    Vendor
    Philips
    Product
    Intellivue Mp2
    Vendor
    Philips
    Product
    Intellivue Mp2 Firmware
    Vendor
    Philips
    Product
    Intellivue Mp30
    Vendor
    Philips
    Product
    Intellivue Mp30 Firmware
    Vendor
    Philips
    Product
    Intellivue Mp50
    Vendor
    Philips
    Product
    Intellivue Mp50 Firmware
    Vendor
    Philips
    Product
    Intellivue Mp70
    Vendor
    Philips
    Product
    Intellivue Mp70 Firmware
    Vendor
    Philips
    Product
    Intellivue Mx100
    Vendor
    Philips
    Product
    Intellivue Mx100 Firmware
    Vendor
    Philips
    Product
    Intellivue Mx400
    Vendor
    Philips
    Product
    Intellivue Mx400 Firmware
    Vendor
    Philips
    Product
    Intellivue Mx450
    Vendor
    Philips
    Product
    Intellivue Mx450 Firmware
    Vendor
    Philips
    Product
    Intellivue Mx500
    Vendor
    Philips
    Product
    Intellivue Mx500 Firmware
    Vendor
    Philips
    Product
    Intellivue Mx550
    Vendor
    Philips
    Product
    Intellivue Mx550 Firmware
    Vendor
    Philips
    Product
    Intellivue Mx700
    Vendor
    Philips
    Product
    Intellivue Mx700 Firmware
    Vendor
    Philips
    Product
    Intellivue Mx800
    Vendor
    Philips
    Product
    Intellivue Mx800 Firmware
    Vendor
    Philips
    Product
    Intellivue Np90
    Vendor
    Philips
    Product
    Intellivue Np90 Firmware
    Vendor
    Philips
    Product
    Intellivue X2
    Vendor
    Philips
    Product
    Intellivue X2 Firmware
    Vendor
    Philips
    Product
    Intellivue X3
    Vendor
    Philips
    Product
    Intellivue X3 Firmware

    Exploits

    No exploit reference

    Common Attack Pattern Enumeration and Classification (CAPEC)

    No CAPEC recorded yet

    Common Vulnerability Scoring System

    Attack Vector
    Network
    Adjacent
    Local
    Physical
    Privileges Required
    None
    Low
    High
    User Interaction
    None
    Required
    Scope
    Unchanged
    Changed
    Confidentiality
    None
    Low
    High
    Integrity
    None
    Low
    High
    Availability
    None
    Low
    High