CVE Feed

    Dashboard / CVE / CVE-2018-11422

    CVE-2018-11422

    Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. Any commands (including device reboot, configuration download or upload, or firmware upgrade) are accepted and executed by the device without authentication.

    Published:Jul 3, 2019
    Last Modified:Nov 21, 2024
    EPS:Jul 3, 2019
    EPSS Score:0.0023
    CVSS Score:9.8

    Affected Products

    Vendor
    Moxa
    Product
    Oncell G3150-hspa
    Vendor
    Moxa
    Product
    Oncell G3150-hspa-t
    Vendor
    Moxa
    Product
    Oncell G3150-hspa-t Firmware
    Vendor
    Moxa
    Product
    Oncell G3150-hspa Firmware

    Exploits

    No exploit reference

    Related CVEs

    Common Vulnerability Scoring System

    Attack Vector
    Network
    Adjacent
    Local
    Physical
    Privileges Required
    None
    Low
    High
    User Interaction
    None
    Required
    Scope
    Unchanged
    Changed
    Confidentiality
    None
    Low
    High
    Integrity
    None
    Low
    High
    Availability
    None
    Low
    High