CVE Feed

    Dashboard / CVE / CVE-2018-4858

    CVE-2018-4858

    A vulnerability has been identified in IEC 61850 system configurator (All versions < V5.80), DIGSI 5 (affected as IEC 61850 system configurator is incorporated) (All versions < V7.80), DIGSI 4 (All versions < V4.93), SICAM PAS/PQS (All versions < V8.11), SICAM PQ Analyzer (All versions < V3.11), SICAM SCC (All versions < V9.02 HF3). A service of the affected products listening on all of the host's network interfaces on either port 4884/TCP, 5885/TCP, or port 5886/TCP could allow an attacker to either exfiltrate limited data from the system or to execute code with Microsoft Windows user permissions. Successful exploitation requires an attacker to be able to send a specially crafted network request to the vulnerable service and a user interacting with the service's client application on the host. In order to execute arbitrary code with Microsoft Windows user permissions, an attacker must be able to plant the code in advance on the host by other means. The vulnerability has limited impact to confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

    Published:Jul 9, 2018
    Last Modified:Nov 21, 2024
    EPS:Jul 9, 2018
    EPSS Score:0.0043
    CVSS Score:7.8

    Affected Products

    Vendor
    Siemens
    Product
    Digsi 4
    Vendor
    Siemens
    Product
    Digsi 4 Firmware
    Vendor
    Siemens
    Product
    Digsi 5
    Vendor
    Siemens
    Product
    Digsi 5 Firmware
    Vendor
    Siemens
    Product
    Ec 61850 System Configurator
    Vendor
    Siemens
    Product
    Ec 61850 System Configurator Firmware
    Vendor
    Siemens
    Product
    Sicam Pas\/pqs
    Vendor
    Siemens
    Product
    Sicam Pq Analyzer
    Vendor
    Siemens
    Product
    Sicam Pq Analyzer Firmware
    Vendor
    Siemens
    Product
    Sicam Scc
    Vendor
    Siemens
    Product
    Sicam Scc Firmware

    Exploits

    No exploit reference

    Common Weakness Enumeration

    Common Vulnerability Scoring System

    Attack Vector
    Network
    Adjacent
    Local
    Physical
    Privileges Required
    None
    Low
    High
    User Interaction
    None
    Required
    Scope
    Unchanged
    Changed
    Confidentiality
    None
    Low
    High
    Integrity
    None
    Low
    High
    Availability
    None
    Low
    High