CVE Feed

    Dashboard / CVE / CVE-2019-13379

    CVE-2019-13379

    On AVTECH Room Alert 3E devices before 2.2.5, an attacker with access to the device's web interface may escalate privileges from an unauthenticated user to administrator by performing a cmd.cgi?action=ResetDefaults&src=RA reset and using the default credentials to get in.

    Published:Jul 7, 2019
    Last Modified:Nov 21, 2024
    EPS:Jul 7, 2019
    EPSS Score:0.08813
    CVSS Score:8.8

    Affected Products

    Vendor
    Avtech
    Product
    Room Alert 3e
    Vendor
    Avtech
    Product
    Room Alert 3e Firmware

    Common Attack Pattern Enumeration and Classification (CAPEC)

    No CAPEC recorded yet

    Common Vulnerability Scoring System

    Attack Vector
    Network
    Adjacent
    Local
    Physical
    Privileges Required
    None
    Low
    High
    User Interaction
    None
    Required
    Scope
    Unchanged
    Changed
    Confidentiality
    None
    Low
    High
    Integrity
    None
    Low
    High
    Availability
    None
    Low
    High