CVE Feed

    Dashboard / CVE / CVE-2023-25187

    CVE-2023-25187

    An issue was discovered on NOKIA Airscale ASIKA Single RAN devices before 21B. Nokia Single RAN commissioning procedures do not change (factory-time installed) default SSH public/private key values that are specific to a network operator. As a result, the CSP internal BTS network SSH server (disabled by default) continues to apply the default SSH public/private key values. These keys don't give access to BTS, because service user authentication is username/password-based on top of SSH. Nokia factory installed default SSH keys are meant to be changed from operator-specific values during the BTS deployment commissioning phase. However, before the 21B release, BTS commissioning manuals did not provide instructions to change default SSH keys (to BTS operator-specific values). This leads to a possibility for malicious operations staff (inside a CSP network) to attempt MITM exploitation of BTS service user access, during the moments that SSH is enabled for Nokia service personnel to perform troubleshooting activities.

    Published:Jun 16, 2023
    Last Modified:Dec 12, 2024
    EPS:Jun 16, 2023
    EPSS Score:0.00144
    CVSS Score:6.3

    Affected Products

    Vendor
    Nokia
    Product
    Asika Airscale
    Vendor
    Nokia
    Product
    Asika Airscale Firmware

    Common Weakness Enumeration

    Common Vulnerability Scoring System

    Attack Vector
    Network
    Adjacent
    Local
    Physical
    Privileges Required
    None
    Low
    High
    User Interaction
    None
    Required
    Scope
    Unchanged
    Changed
    Confidentiality
    None
    Low
    High
    Integrity
    None
    Low
    High
    Availability
    None
    Low
    High