CVE Feed

    Dashboard / CVE / CVE-2023-43630

    CVE-2023-43630

    PCR14 is not in the list of PCRs that seal/unseal the “vault” key, but due to the change that was implemented in commit “7638364bc0acf8b5c481b5ce5fea11ad44ad7fd4”, fixing this issue alone would not solve the problem of the config partition not being measured correctly. Also, the “vault” key is sealed/unsealed with SHA1 PCRs instead of SHA256. This issue was somewhat mitigated due to all of the PCR extend functions updating both the values of SHA256 and SHA1 for a given PCR ID. However, due to the change that was implemented in commit “7638364bc0acf8b5c481b5ce5fea11ad44ad7fd4”, this is no longer the case for PCR14, as the code in “measurefs.go” explicitly updates only the SHA256 instance of PCR14, which means that even if PCR14 were to be added to the list of PCRs sealing/unsealing the “vault” key, changes to the config partition would still not be measured. An attacker could modify the config partition without triggering the measured boot, this could result in the attacker gaining full control over the device with full access to the contents of the encrypted “vault”

    Published:Sep 20, 2023
    Last Modified:Nov 21, 2024
    EPS:Sep 20, 2023
    EPSS Score:0.00013
    CVSS Score:8.8

    Affected Products

    Vendor
    Linuxfoundation
    Product
    Edge Virtualization Engine

    Exploits

    No exploit reference

    Common Vulnerability Scoring System

    Attack Vector
    Network
    Adjacent
    Local
    Physical
    Privileges Required
    None
    Low
    High
    User Interaction
    None
    Required
    Scope
    Unchanged
    Changed
    Confidentiality
    None
    Low
    High
    Integrity
    None
    Low
    High
    Availability
    None
    Low
    High