CVE-2025-60689
An unauthenticated command injection vulnerability exists in the Start_EPI function of the httpd binary on Linksys E1200 v2 routers (Firmware E1200_v2.0.11.001_us.tar.gz). The vulnerability occurs because user-supplied CGI parameters (wl_ant, wl_ssid, wl_rate, ttcp_num, ttcp_ip, ttcp_size) are concatenated into system command strings without proper sanitization and executed via wl_exec_cmd. Successful exploitation allows remote attackers to execute arbitrary commands on the device without authentication.
Published:Nov 13, 2025
Last Modified:Jul 22, 2026
EPS:Nov 13, 2025
EPSS Score:0.0853
CVSS Score:5.4
Affected Products
Vendor
Product
Action
Vendor
Linksys
Product
E1200
Linksys
E1200
Vendor
Linksys
Product
E1200 Firmware
Linksys
E1200 Firmware
Exploits
Common Weakness Enumeration
Common Attack Pattern Enumeration and Classification (CAPEC)
Related CVEs
Common Vulnerability Scoring System
Attack Vector
Network
Adjacent
Local
Physical
Privileges Required
None
Low
High
User Interaction
None
Required
Scope
Unchanged
Changed
Confidentiality
None
Low
High
Integrity
None
Low
High
Availability
None
Low
High