CVE Feed

    Dashboard / CVE / CVE-2025-9274

    CVE-2025-9274

    Oxford Instruments Imaris Viewer IMS File Parsing Uninitialized Pointer Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Oxford Instruments Imaris Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of IMS files. The issue results from the lack of proper initialization of a pointer prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-21657.

    Published:Sep 2, 2025
    Last Modified:Sep 15, 2025
    EPS:Sep 2, 2025
    EPSS Score:0.0005
    CVSS Score:7.8

    Affected Products

    Vendor
    Oxford Instruments
    Product
    Imaris Viewer
    Vendor
    Oxinst
    Product
    Imaris Viewer

    Exploits

    No exploit reference

    Common Weakness Enumeration

    Common Attack Pattern Enumeration and Classification (CAPEC)

    No CAPEC recorded yet

    Common Vulnerability Scoring System

    Attack Vector
    Network
    Adjacent
    Local
    Physical
    Privileges Required
    None
    Low
    High
    User Interaction
    None
    Required
    Scope
    Unchanged
    Changed
    Confidentiality
    None
    Low
    High
    Integrity
    None
    Low
    High
    Availability
    None
    Low
    High