CVE Feed

    Dashboard / CVE / CVE-2026-12473

    CVE-2026-12473

    Two data sources (DICOMWebProxy and DICOMJSON) shipped in the default configuration fetch an arbitrary URL parameter without validation. A global authentication service in OHIF automatically injects the authenticated user's OIDC Bearer token into the resulting requests, sending it to the attacker-controlled server. DICOMweb data sources are not impacted.

    Published:Jun 25, 2026
    Last Modified:Jun 26, 2026
    EPS:Jun 25, 2026
    EPSS Score:0.00232
    CVSS Score:8.2

    Affected Products

    Vendor
    Open Health Imaging Foundation
    Product
    Dicom Web Viewer Framework

    Exploits

    No exploit reference

    Common Attack Pattern Enumeration and Classification (CAPEC)

    Common Vulnerability Scoring System

    Attack Vector
    Network
    Adjacent
    Local
    Physical
    Privileges Required
    None
    Low
    High
    User Interaction
    None
    Required
    Scope
    Unchanged
    Changed
    Confidentiality
    None
    Low
    High
    Integrity
    None
    Low
    High
    Availability
    None
    Low
    High