CVE Feed

    Dashboard / CVE / CVE-2026-79976

    CVE-2026-79976

    The MCTP-over-I2C+GPIO target binding in subsys/pmci/mctp/mctp_i2c_gpio_target.c emulates a small pseudo-register file, where the bus controller first writes a register number and then writes or reads payload bytes. The selected register (b->reg_addr) and the data-phase flag (b->rxtx) were never cleared when the controller issued an I2C STOP, so after a completed transfer the target still had a data register selected while the packet buffer that register refers to had already been consumed and set to NULL by mctp_i2c_gpio_target_stop(). A controller on the bus can re-enter the same branch of mctp_i2c_gpio_target_stop() with a NULL buffer using two ordinary transactions and no authentication: first a normal packet write to MCTP_I2C_GPIO_RX_MSG_ADDR followed by STOP (which delivers and frees b->rx_pkt), then a bare read transaction followed by STOP. The failing read_requested() call leaves the stale state untouched and the I2C driver still delivers the STOP callback, which then calls mctp_bus_rx() with a NULL packet. The symmetric case exists on the transmit side, where the stale MCTP_I2C_GPIO_TX_MSG_ADDR selection dereferences b->tx_pkt->end after b->tx_pkt has been cleared and additionally signals b->tx_complete a second time, causing the next outbound packet to be dropped. The dereference happens in the I2C target interrupt handler, so on any target that traps accesses to address 0 the result is a fatal exception and a device reset or halt — a denial of service inflicted by any device able to act as controller on the shared management bus (for example compromised firmware on a peer MCTP endpoint or on the BMC). On parts where address 0 is readable, the impact degrades to a malformed packet buffer being handed to the MCTP stack and lost transmit packets. No attacker-controlled value is written and no confidentiality or integrity boundary is crossed. The fix resets b->reg_addr to MCTP_I2C_GPIO_INVALID_ADDR and clears b->rxtx at every STOP, so a new register must be selected before any data phase can run again. Only builds that opt into the experimental CONFIG_MCTP subsystem with CONFIG_MCTP_I2C_GPIO_TARGET=y are affected.

    Published:Oct 21, 2026
    Last Modified:Oct 23, 2026
    EPS:Oct 21, 2026
    EPSS Score:0.00207
    CVSS Score:7.1

    Affected Products

    Vendor
    Zephyrproject
    Product
    Zephyr

    Exploits

    No exploit reference

    Common Weakness Enumeration

    Common Attack Pattern Enumeration and Classification (CAPEC)

    No CAPEC recorded yet

    Related CVEs

    Common Vulnerability Scoring System

    Attack Vector
    Network
    Adjacent
    Local
    Physical
    Privileges Required
    None
    Low
    High
    User Interaction
    None
    Required
    Scope
    Unchanged
    Changed
    Confidentiality
    None
    Low
    High
    Integrity
    None
    Low
    High
    Availability
    None
    Low
    High