Sielcosistemi

    Dashboard / Vendors

    Products: 2
    Vulnerabilities: 11
    Known Exploited: 0
    9
    Critical Level Threats
    1
    High Level Threats
    1
    Medium Level Threats
    0
    Low Level Threats

    Vulnerabilities

    100806040200
    JanFebMarAprMayJunJulAugSepOctNovDec
    Critical Level Threats
    High Level Threats
    Medium Level Threats
    Low Level Threats

    Products Security index

    Actions
    Items Per Page

    Vulnerabilities

    CVE-2017-5161

    An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to Version 3.02.01. An uncontrolled search path element (DLL Hijacking) vulnerability has been identified. Exploitation of this vulnerability could give an attacker access to the system with the same level of privilege as the application that utilizes the malicious DLL.

    Last Modified: Apr 20, 2025
    Published: Feb 13, 2017

    CVE-2012-4356

    Multiple directory traversal vulnerabilities in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allow remote attackers to read arbitrary files via port-46824 TCP packets specifying a file-open operation with opcode 0x78 and a .. (dot dot) in a pathname, followed by a file-read operation with opcode (1) 0x96, (2) 0x97, or (3) 0x98.

    Last Modified: Apr 11, 2025
    Published: Aug 19, 2012

    CVE-2012-4357

    Array index error in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 might allow remote attackers to execute arbitrary code by referencing, within a port-46824 TCP packet, an invalid file-pointer index that leads to execution of an EnterCriticalSection code block.

    Last Modified: Apr 11, 2025
    Published: Aug 19, 2012

    CVE-2012-4358

    Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 do not validate the return value of the realloc function, which allows remote attackers to cause a denial of service (invalid 0x00 write operation and daemon crash) or possibly have unspecified other impact via a port-46824 TCP packet with a crafted positive integer after the opcode.

    Last Modified: Apr 11, 2025
    Published: Aug 19, 2012

    CVE-2012-4353

    Stack-based buffer overflow in RunTime.exe in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allows remote attackers to execute arbitrary code via a crafted port-46824 TCP packet that triggers an incorrect file-open attempt by the _TCPIPS_BinOpenFileFP function, a different vulnerability than CVE-2012-3815. NOTE: some of these details are obtained from third party information.

    Last Modified: Apr 11, 2025
    Published: Aug 19, 2012
    Items Per Page