CVE-2022-31204
Dashboard / Vulnerabilities / CVE-2022-31204
CVE-2022-31204
Published: 26 Jul 2022Last Modified: 11 Mar 2026
Summary:
Details: Omron CS series, CJ series, and CP series PLCs through 2022-05-18 use cleartext passwords. They feature a UM Protection setting that allows users or system integrators to configure a password in order to restrict sensitive engineering operations (such as project/logic uploads and downloads). This password is set using the OMRON FINS command Program Area Protect and unset using the command Program Area Protect Clear, both of which are transmitted in cleartext.
References: , https://www.forescout.com/blog/, https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-02
Affected packages
Package
Name:
Purl:
Affected ranges
Type: N/A
Events:
Introduced- None
Fixed -None
Affected versions
Common Vulnerability Scoring System
Attack Vector
Network
Adjacent
Local
Physical
Privileges Required
None
Low
High
User Interaction
None
Required
Scope
Unchanged
Changed
Confidentiality
None
Low
High
Integrity
None
Low
High
Availability
None
Low
High