SUSE-SU-2016:3162-1
Dashboard / Vulnerabilities / SUSE-SU-2016:3162-1
SUSE-SU-2016:3162-1
Summary: Security update for pacemaker
Details: This update for pacemaker fixes one security issue and several non-security issues. The following security issue has been fixed: - libcrmcommon: Fix improper IPC guarding. (bsc#1007433, CVE-2016-7035) The following non-security issues have been fixed: - Add logrotate to reqs of pacemaker-cli. - Add $remote_fs dependencies to the init scripts. - all: Clarify licensing and copyrights. - attrd,ipc: Prevent possible segfault on exit. (bsc#986056) - attrd, libcrmcommon: Validate attrd requests better. - attrd_updater: Fix usage of HAVE_ATOMIC_ATTRD. - cib/fencing: Set status callback before connecting to cluster. (bsc#974108) - ClusterMon: Fix to avoid matching other process with the same PID. - crmd: Acknowledge cancellation operations for remote connection resources. (bsc#976865) - crmd: Avoid timeout on older peers when cancelling a resource operation. - crmd: Record pending operations in the CIB before they are performed. (bsc#1003565) - crmd: Clear remote node operation history only when it comes up. - crmd: Clear remote node transient attributes on disconnect. (bsc#981489) - crmd: Don't abort transitions for CIB comment changes. - crmd: Ensure the R_SHUTDOWN is set whenever we ask the DC to shut us down. - crmd: Get full action information earlier. (bsc#981731) - crmd: Graceful proxy shutdown is now tested. (bsc#981489) - crmd: Keep a state of LRMD in the DC node latest. - crmd,lrmd,liblrmd: Use defined constants for lrmd IPC operations. (bsc#981489) - crmd: Mention that graceful remote shutdowns may cause connection failures. (bsc#981489) - crmd/pengine: Handle on-fail=ignore properly. (bsc#981731) - crmd/pengine: Implement on-fail=ignore without allow-fail. (bsc#981731) - crmd: Remove dead code. (bsc#981731) - crmd: Rename action number variable in process_graph_event(). (bsc#981731) - crmd: Resend the shutdown request if the DC forgets. - crmd: Respect start-failure-is-fatal even for artificially injected events. (bsc#981731) - crmd: Set remote flag when gracefully shutting down remote nodes. (bsc#981489) - crmd: Set the shutdown transient attribute in response to LRMD_IPC_OP_SHUTDOWN_REQ from remote nodes. (bsc#981489) - crmd: Support graceful pacemaker_remote stops. (bsc#981489) - crmd: Take start-delay into account for the timeout of the action timer. (bsc#977258) - crmd: Use defined constant for magic 'direct nack' RC. (bsc#981731) - crmd: Use proper resource agent name when caching metadata. - crmd: When node load was reduced, crmd carries out a feasible action. - crm_mon: Avoid logging errors for any CIB changes that we don't care about. (bsc#986931) - crm_mon: Consistently print ms resource state. - crm_mon: Do not call setenv with null value. - crm_mon: Do not log errors for the known CIB changes that should be ignored. (bsc#986931) - crm_mon: Fix time formatting on x32. - cts: Avoid kill usage error if DummySD stop called when already stopped. - CTS: Get Reattach test working again and up-to-date. (bsc#953192) - cts: Simulate pacemaker_remote failure with kill. (bsc#981489) - fencing/fence_legacy: Search capable devices by querying them through 'list' action for cluster-glue stonith agents. (bsc#986265) - fencing: Record the last known names of nodes to make sure fencing requested with nodeid works. (bsc#974108) - libais,libcluster,libcrmcommon,liblrmd: Don't use %z specifier. - libcib,libfencing,libtransition: Handle memory allocation errors without CRM_CHECK(). - lib: Correction of the deletion of the notice registration. - libcrmcommon: Correct directory name in log message. - libcrmcommon: Ensure crm_time_t structure is fully initialized by API calls. - libcrmcommon: Log XML comments correctly. - libcrmcommon: Properly handle XML comments when comparing v2 patchset diffs. - libcrmcommon: Really ensure crm_time_t structure is fully initialized by API calls. - libcrmcommon: Remove extraneous format specifier from log message. - libcrmcommon: Report errors consistently when waiting for data on connection. (bsc#986644) - libfencing: Report added node ID correctly. - liblrmd: Avoid memory leak when closing or deleting lrmd connections. - libpengine: Allow pe_order_same_node option for constraints. - libpengine: Log message when stonith disabled, not enabled. - libpengine: Only log startup-fencing warning once. - libtransition: Potential memory leak if unpacking action fails. - lrmd: Handle shutdown a little more cleanly. (bsc#981489) - lrmd,libcluster: Ensure g_hash_table_foreach() is never passed a null table. - lrmd,liblrmd: Add lrmd IPC operations for requesting and acknowledging shutdown. (bsc#981489) - lrmd: Make proxied IPC providers/clients opaque. (bsc#981489) - mcp: Improve comments for sysconfig options. - pacemaker_remote: Set LSB Provides header to the service name. - pacemaker_remote: Support graceful stops. (bsc#981489) - PE: Correctly update the dependent actions of un-runnable clones. - PE: Honor the shutdown transient attributes for remote nodes. (bsc#981489) - pengine: Avoid memory leak when invalid constraint involves set. - pengine: Avoid null dereference in new same-node ordering option. - pengine: Avoid transition loop for start-then-stop + unfencing. - pengine: Avoid use-after-free with location constraint + sets + templates. - pengine: Better error handling when unpacking sets in location constraints. - pengine: Consider resource failed if any of the configured monitor operations failed. (bsc#972187) - pengine: Correction of the record judgment of the failed information. - pengine: Do not fence a maintenance node if it shuts down cleanly. (bsc#1000743) - pengine: Correctly set the environment variable 'OCF_RESKEY_CRM_meta_timeout' when 'start-delay' is configured. (bsc#977258) - pengine: Only set unfencing constraints once. - pengine: Organize order of actions for master resources in anti-colocations. (bsc#977800) - pengine: Organize order of actions for slave resources in anti-colocations. (bsc#977800) - pengine: Properly order stop actions relative to stonith. - pengine: Respect asymmetrical ordering when trying to move resources. (bsc#977675) - pengine: Set OCF_RESKEY_CRM_meta_notify_active_* for multistate resources. - pengine,tools: Display pending resource state by default when it's available. (bsc#986201) - ping: Avoid temp files in fping_check. (bsc#987348) - ping: Avoid temporary files for fping check. (bsc#987348) - ping: Log sensible error when /tmp is full. (bsc#987348) - ping resource: Use fping6 for IPv6 hosts. (bsc#976271) - RA/SysInfo: Reset the node attribute '#health_disk' to 'green' when there's sufficient free disk. (bsc#975079) - remote: Allow cluster and remote LRM API versions to diverge. (bsc#1009076) - remote: Correctly calculate the remaining timeouts when receiving messages. (bsc#986644) - resources: Use OCF version tagging correctly. - services: Correctly clean up service actions for non-dbus case. - spec: fence_pcmk only eligible for Pacemaker+CMAN. - stonithd: Correction of the wrong connection process name. - sysconfig: Minor tweaks (typo, wording). - tools: Avoid memory leaks in crm_resource --restart. - tools: Avoid memory leak when crm_mon unpacks constraints. - tools: Correctly count starting resources when doing crm_resource --restart. - tools: crm_resource -T option should not be hidden anymore. - tools: crm_standby --version/--help should work without cluster. - tools: Do not send command lines to syslog. (bsc#986676) - tools: Do not assume all resources restart on same node with crm_resource --restart. - tools: Don't require node to be known to crm_resource when deleting attribute. - tools: Properly handle crm_resource --restart with a resource in a group. - tools: Remember any existing target-role when doing crm_resource --restart. - various: Issues discovered via valgrind and coverity. Additionally, the following references have been added to the changelog: bsc#970733, fate#318381, bsc#1002767, CVE-2016-7797, bsc#971129
References: https://www.suse.com/support/update/announcement/2016/suse-su-20163162-1/, https://bugzilla.suse.com/1000743, https://bugzilla.suse.com/1002767, https://bugzilla.suse.com/1003565, https://bugzilla.suse.com/1007433, https://bugzilla.suse.com/1009076, https://bugzilla.suse.com/953192, https://bugzilla.suse.com/970733, https://bugzilla.suse.com/971129, https://bugzilla.suse.com/972187, https://bugzilla.suse.com/974108, https://bugzilla.suse.com/975079, https://bugzilla.suse.com/976271, https://bugzilla.suse.com/976865, https://bugzilla.suse.com/977258, https://bugzilla.suse.com/977675, https://bugzilla.suse.com/977800, https://bugzilla.suse.com/981489, https://bugzilla.suse.com/981731, https://bugzilla.suse.com/986056, https://bugzilla.suse.com/986201, https://bugzilla.suse.com/986265, https://bugzilla.suse.com/986644, https://bugzilla.suse.com/986676, https://bugzilla.suse.com/986931, https://bugzilla.suse.com/987348, https://www.suse.com/security/cve/CVE-2016-7035, https://www.suse.com/security/cve/CVE-2016-7797
Affected packages
Package
Name: pacemaker
Purl: pkg:rpm/suse/pacemaker&distro=SUSE%20Linux%20Enterprise%20High%20Availability%20Extension%2011%20SP4
Affected ranges
Type: ECOSYSTEM
Events: