CVE-2024-50558
Last Modified: 13 Nov 2024A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2). Affected devices improperly manage access control for read-only users. This could allow an attacker to cause a temporary denial of service condition.
CVE-2024-50557
Last Modified: 20 Nov 2024A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2). Affected devices do not properly validate input in configuration fields of the iperf functionality. This could allow an unauthenticated remote attacker to execute arbitrary code on the device.
CVE-2024-50313
Last Modified: 27 Aug 2025A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.16.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions < V10.12.7 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions < V10.6.15 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions < V9.24.29 only if the basic authentication mechanism is used by the application). The basic authentication implementation of affected applications contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures.
CVE-2024-50310
Last Modified: 13 Nov 2024A vulnerability has been identified in SIMATIC CP 1543-1 V4.0 (6GK7543-1AX10-0XE0) (All versions >= V4.0.44 < V4.0.50). Affected devices do not properly handle authorization. This could allow an unauthenticated remote attacker to gain access to the filesystem.
CVE-2024-47942
Last Modified: 13 Nov 2024A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 9). The affected applications suffer from a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system.
CVE-2024-47941
Last Modified: 13 Nov 2024A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 9). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-47940
Last Modified: 13 Nov 2024A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 9). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-47808
Last Modified: 13 Nov 2024A vulnerability has been identified in SINEC NMS (All versions < V3.0 SP1). The affected application contains a database function, that does not properly restrict the permissions of users to write to the filesystem of the host system. This could allow an authenticated medium-privileged attacker to write arbitrary content to any location in the filesystem of the host system.
CVE-2024-47783
Last Modified: 13 Nov 2024A vulnerability has been identified in SIPORT (All versions < V3.4.0). The affected application improperly assigns file permissions to installation folders. This could allow a local attacker with an unprivileged account to override or modify the service executables and subsequently gain elevated privileges.
CVE-2024-46894
Last Modified: 20 Aug 2025A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly validate authorization of a user to query the "/api/sftp/users" endpoint. This could allow an authenticated remote attacker to gain knowledge about the list of configured users of the SFTP service and also modify that configuration.
CVE-2024-46892
Last Modified: 13 Nov 2024A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly invalidate sessions when the associated user is deleted or disabled or their permissions are modified. This could allow an authenticated attacker to continue performing malicious actions even after their user account has been disabled.
CVE-2024-46891
Last Modified: 20 Aug 2025A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly restrict the size of generated log files. This could allow an unauthenticated remote attacker to trigger a large amount of logged events to exhaust the system's resources and create a denial of service condition.
CVE-2024-46890
Last Modified: 13 Nov 2024A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly validate input sent to specific endpoints of its web API. This could allow an authenticated remote attacker with high privileges on the application to execute arbitrary code on the underlying OS.
CVE-2024-46889
Last Modified: 13 Nov 2024A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application uses hard-coded cryptographic key material to obfuscate configuration files. This could allow an attacker to learn that cryptographic key material through reverse engineering of the application binary and decrypt arbitrary backup files.
CVE-2024-46888
Last Modified: 13 Nov 2024A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly sanitize user provided paths for SFTP-based file up- and downloads. This could allow an authenticated remote attacker to manipulate arbitrary files on the filesystem and achieve arbitrary code execution on the device.
CVE-2024-44102
Last Modified: 15 Nov 2024A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions < V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.
CVE-2024-36140
Last Modified: 15 Nov 2024A vulnerability has been identified in OZW672 (All versions < V5.2), OZW772 (All versions < V5.2). The user accounts tab of affected devices is vulnerable to stored cross-site scripting (XSS) attacks. This could allow an authenticated remote attacker to inject arbitrary JavaScript code that is later executed by another authenticated victim user with potential higher privileges than the attacker.
CVE-2024-29119
Last Modified: 15 Nov 2024A vulnerability has been identified in Spectrum Power 7 (All versions < V24Q3). The affected product contains several root-owned SUID binaries that could allow an authenticated local attacker to escalate privileges.
CVE-2023-32736
Last Modified: 15 Apr 2026A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2024-11004
Last Modified: 4 Apr 2025Reflected XSS in Ivanti Connect Secure before version 22.7R2.1 and Ivanti Policy Secure before version 22.7R1.1 allows a remote unauthenticated attacker to obtain admin privileges. User interaction is required.
CVE-2024-11005
Last Modified: 17 Jan 2025Command injection in Ivanti Connect Secure before version 22.7R2.1 (Not Applicable to 9.1Rx) and Ivanti Policy Secure before version 22.7R1.1 (Not Applicable to 9.1Rx) allows a remote authenticated attacker with admin privileges to achieve remote code execution.
CVE-2024-11006
Last Modified: 17 Jan 2025Command injection in Ivanti Connect Secure before version 22.7R2.1 (Not Applicable to 9.1Rx) and Ivanti Policy Secure before version 22.7R1.1 (Not Applicable to 9.1Rx) allows a remote authenticated attacker with admin privileges to achieve remote code execution.
CVE-2024-11007
Last Modified: 22 Nov 2024Command injection in Ivanti Connect Secure before version 22.7R2.1 (Not Applicable to 9.1Rx) and Ivanti Policy Secure before version 22.7R1.1 (Not Applicable to 9.1Rx) allows a remote authenticated attacker with admin privileges to achieve remote code execution.
CVE-2024-10971
Last Modified: 27 Jun 2025Improper access control in the Password History feature in Devolutions DVLS 2024.3.6 and earlier allows a malicious authenticated user to obtain sensitive data via faulty permission.
CVE-2024-11130
Last Modified: 15 Nov 2024A vulnerability was found in ZZCMS up to 2023. It has been rated as problematic. Affected by this issue is some unknown functionality of the file /admin/msg.php. The manipulation of the argument keyword leads to cross site scripting. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-11127
Last Modified: 15 Nov 2024A vulnerability was found in code-projects Job Recruitment up to 1.0. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file admin.php. The manipulation of the argument userid leads to sql injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-11125
Last Modified: 15 Nov 2024A vulnerability was found in GetSimpleCMS 3.3.16 and classified as problematic. This issue affects some unknown processing of the file /admin/profile.php. The manipulation leads to cross-site request forgery. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-11124
Last Modified: 15 Nov 2024A vulnerability has been found in TimGeyssens UIOMatic 5 and classified as critical. This vulnerability affects unknown code of the file /src/UIOMatic/wwwroot/backoffice/resources/uioMaticObject.r. The manipulation leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10245
Last Modified: 15 Apr 2026The Relais 2FA plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 1.0. This is due to incorrect authentication and capability checking in the 'rl_do_ajax' function. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the email.
CVE-2024-11123
Last Modified: 27 Aug 2025A vulnerability, which was classified as problematic, was found in 上海灵当信息科技有限公司 Lingdang CRM up to 8.6.4.3. This affects an unknown part of the file /crm/data/pdf.php. The manipulation of the argument url with the input ../config.inc.php leads to path traversal. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-11122
Last Modified: 27 Aug 2025A vulnerability, which was classified as critical, has been found in 上海灵当信息科技有限公司 Lingdang CRM up to 8.6.4.3. Affected by this issue is some unknown functionality of the file /crm/wechatSession/index.php?msgid=1&operation=upload. The manipulation of the argument file leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-11121
Last Modified: 27 Aug 2025A vulnerability classified as critical was found in 上海灵当信息科技有限公司 Lingdang CRM up to 8.6.4.3. Affected by this vulnerability is an unknown functionality of the file /crm/WeiXinApp/marketing/index.php?module=Users&action=getActionList. The manipulation of the argument userid leads to sql injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-10323
Last Modified: 8 Apr 2026The JetWidgets For Elementor plugin for WordPress is vulnerable to Stored Cross-Site Scripting via REST API SVG File uploads in all versions up to, and including, 1.0.18 due to insufficient input sanitization and output escaping. This makes it possible for authenticated attackers, with Author-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses the SVG file.
CVE-2024-10179
Last Modified: 15 Apr 2026The Slickstream: Engagement and Conversions plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the plugin's slick-grid shortcode in all versions up to, and including, 1.4.4 due to insufficient input sanitization and output escaping on user supplied attributes. This makes it possible for authenticated attackers, with contributor-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page.
CVE-2024-9836
Last Modified: 15 May 2025The RSS Feed Widget WordPress plugin before 3.0.0 does not validate and escape some of its shortcode attributes before outputting them back in a page/post where the shortcode is embed, which could allow users with the contributor role and above to perform Stored Cross-Site Scripting attacks.
CVE-2024-9835
Last Modified: 15 May 2025The RSS Feed Widget WordPress plugin before 3.0.1 does not escape the $_SERVER['REQUEST_URI'] parameter before outputting it back in an attribute, which could lead to Reflected Cross-Site Scripting in old web browsers
CVE-2024-47799
Last Modified: 15 Apr 2026Exposure of sensitive system information to an unauthorized control sphere issue exists in Mesh Wi-Fi router RP562B firmware version v1.0.2 and earlier. If this vulnerability is exploited, a network-adjacent authenticated attacker may obtain information of the other devices connected through the Wi-Fi.
CVE-2024-10790
Last Modified: 15 Apr 2026The Admin and Site Enhancements (ASE) plugin for WordPress is vulnerable to Stored Cross-Site Scripting via SVG File uploads in all versions up to, and including, 7.5.1 due to insufficient input sanitization and output escaping. This makes it possible for authenticated attackers, with custom-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses the SVG file. This feature must be enabled, and for specific roles in order to be exploitable.
CVE-2024-9357
Last Modified: 15 Apr 2026The xili-tidy-tags plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the 'action' parameter in all versions up to, and including, 1.12.04 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
CVE-2024-45827
Last Modified: 15 Apr 2026Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Mesh Wi-Fi router RP562B firmware version v1.0.2 and earlier. If this vulnerability is exploited, a network-adjacent authenticated attacker may execute an arbitrary OS command.
CVE-2024-29075
Last Modified: 15 Apr 2026Active debug code vulnerability exists in Mesh Wi-Fi router RP562B firmware version v1.0.2 and earlier. If this vulnerability is exploited, a network-adjacent authenticated attacker may obtain or alter the settings of the device .
CVE-2024-48838
Last Modified: 15 Nov 2024Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) a Files or Directories Accessible to External Parties vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker.
CVE-2024-48837
Last Modified: 18 Nov 2024Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) an Execution with Unnecessary Privileges vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution
CVE-2024-49557
Last Modified: 15 Nov 2024Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution.
CVE-2024-10538
Last Modified: 8 Apr 2026The Happy Addons for Elementor plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the before_label parameter in the Image Comparison widget in all versions up to, and including, 3.12.5 due to insufficient input sanitization and output escaping. This makes it possible for authenticated attackers, with Contributor-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page.
CVE-2024-10685
Last Modified: 8 Apr 2026The Contact Form 7 Redirect & Thank You Page plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the 'tab' parameter in all versions up to, and including, 1.0.6 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
CVE-2024-10672
Last Modified: 8 Apr 2026The Multiple Page Generator Plugin – MPG plugin for WordPress is vulnerable to arbitrary file deletion due to insufficient file path validation in the mpg_upsert_project_source_block() function in all versions up to, and including, 4.0.2. This makes it possible for authenticated attackers, with editor-level access and above, to delete limited files on the server.
CVE-2024-10695
Last Modified: 8 Apr 2026The Futurio Extra plugin for WordPress is vulnerable to Information Exposure in all versions up to, and including, 2.0.13 via the 'elementor-template' shortcode due to insufficient restrictions on which posts can be included. This makes it possible for authenticated attackers, with Contributor-level access and above, to extract data from private or draft posts that they should not have access to.
CVE-2024-49558
Last Modified: 15 Nov 2024Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) an Improper Privilege Management vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.
CVE-2024-49560
Last Modified: 15 Nov 2024Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) a command injection vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.
