CVE-2026-25599
Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an attacker to impersonate a legitimate device and inject malicious payloads. This enables the insertion of harmful code directly into the Orca user portal, potentially compromising user accounts, exposing sensitive information, and allowing further unauthorized actions within the portal.
Published:Jun 1, 2026
Last Modified:Jun 2, 2026
EPS:Jun 1, 2026
EPSS Score:0.00018
CVSS Score:6.3
Affected Products
Vendor
Product
Action
Vendor
Orca Energy
Product
Orca Heat Pump
Orca Energy
Orca Heat Pump
Vendor
Orca Energy
Product
Orca User Portal
Orca Energy
Orca User Portal
Exploits
No exploit reference
Common Weakness Enumeration
Common Attack Pattern Enumeration and Classification (CAPEC)
References
Common Vulnerability Scoring System
Attack Vector
Network
Adjacent
Local
Physical
Privileges Required
None
Low
High
User Interaction
None
Required
Scope
Unchanged
Changed
Confidentiality
None
Low
High
Integrity
None
Low
High
Availability
None
Low
High