Products: 6
    Vulnerabilities: 4
    Known Exploited: 0
    3
    Critical Level Threats
    1
    High Level Threats
    0
    Medium Level Threats
    0
    Low Level Threats

    Vulnerabilities

    100806040200
    JanFebMarAprMayJunJulAugSepOctNovDec
    Critical Level Threats
    High Level Threats
    Medium Level Threats
    Low Level Threats

    Products Security index

    Actions
    Items Per Page

    Vulnerabilities

    CVE-2015-3956

    Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior accept drug libraries, firmware updates, pump commands, and unauthorized configuration changes from unauthenticated devices on the host network. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue.

    Last Modified: Nov 21, 2024
    Published: Mar 25, 2019

    CVE-2015-3954

    Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior give unauthenticated users root privileges on Port 23/TELNET by default. An unauthorized user could issue commands to the pump. Hospira recommends that customers close Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue.

    Last Modified: Nov 21, 2024
    Published: Mar 25, 2019

    CVE-2015-3953

    Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue.

    Last Modified: Nov 21, 2024
    Published: Mar 25, 2019

    CVE-2015-3952

    Wireless keys are stored in plain text on Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue.

    Last Modified: Nov 21, 2024
    Published: Mar 25, 2019
    Items Per Page